Minimum requirements
Downloading and installing the mobile app
Physically installing the system
Main menu for navigating between application sections
Detail of active programming
A coloured LED light on the gateway indicates its operating status. If the light is green, it means that the system is working correctly; if the light is red, it means that the gateway is in programming mode. If an operator forgets to exit a setup operation or a device/group details screen, the gateway will automatically return to operating mode after 5 minutes, changing the LED colour from red to green.
Selecting the language at startup
Connecting to the Gateway
Scanning remote modules
NOTE: We recommend registering all lighting fixtures, DALI-2 sensors, and buttons equipped with a remote board before connecting them to the power supply. If there are issues with a device’s connection status, disconnect the gateway from the power supply and restart it.
STATUS OF REGISTERED DEVICES:
1) Device not registered: This status means that the device is connected to the system but has not yet been recognised by the gateway. Make sure the device is powered. The gateway scans devices every minute to check their status. Wait at least one minute for the process to complete.
2) Not connected: This status means that the device is connected to the system, it has been recognised by the gateway, but it is not communicating with the gateway yet. Make sure the device is powered. The gateway scans devices every minute to check their status. Wait at least one minute for the process to complete.
3) Connected: The gateway is communicating with the device.
TESTING THE CONNECTED LIGHTING FIXTURES:
You can check that all connected lamps respond correctly to the system by adjusting their brightness using the light bulb button. This brightness setting is temporary and for testing purposes only. It will revert to normal once you exit the test screen.
Adding Device
Creating a Group
Button to create a device group
Adding Device
Note: When creating and setting up a group, the gateway enters programming mode, interrupting normal system operation. Once you’ve finished setting up the group, you must return to the list of groups. If you forget to do this, the system will automatically resume normal operation 5 minutes after you exit the app.
Click icon to connect new devices to the group
NOTES and WARNINGS:
NOTES and WARNINGS:
Management of the Normally‑Open Push Button Connected to a Group
Notes and Warnings
Button to save the physical button settings
Time in minutes to timeout after pressing the button. Must have a value between 1 and 180 minutes
Go to the main menu and select Gateway to open the related management and setting options.
From this menu you can manage:
Note: Opening the Gateway menu will put the system into programming mode, interrupting normal operation until you exit this section.
In the “Gateway” section of the main menu, you can export the configuration settings to your smartphone and restore them later. On Android devices, the backup file is automatically saved in the documents folder. On iOS devices, you will be prompted to choose a location to save the file. The backup file looks something like this: dismart2-YYMMDD-HHMMSS.db. To restore the configuration settings, you will need to find the backup file on your device.
From the main menu, select “Devices” to view the list of devices connected to the system and open the lamp management page.
This screen displays:
Note: Opening the details page of a lamp will put the system into programming mode, interrupting normal operation until you exit this section.
Changing the lamp name
Button that makes the lamp flash to identify it.
Button to perform dimming tests on the single lamp
Area for connecting or disconnecting from a device group
From the main menu, select “Devices” to view the list of devices connected to the system and open the sensor management page.
This screen displays:
Adjusting the sensor:
The light sensor must be adjusted in the absence of natural light, using a certified lux meter.
Using the calibration management blocks, you can enter a LUX value detected by the certified lux meter, corresponding to the dimming value of the lamps connected to the group. The values recorded in the presets can then serve as a reference for defining the brightness expected during a given time slot.
Replacing the DALI-2 sensor connected to the board:
If you need to replace the sensor connected to the remote board of the DISMART 2.0 system, you can force the new sensor to align with the system by pressing “Scan DALI line again”.
Note: Opening the details page of a lamp will put the system into programming mode, interrupting normal operation until you exit this section.
Access to the device management system
Button to force the gateway to search for the DALI2 device in case of failure to detect the device or replacement of the sensor connected to the remote module.
The gateway clock can be managed via the Gateway Management Menu, under the Gateway Time section.
From here, you can:
Daylight Saving Time
The gateway automatically updates its internal clock based on international daylight saving time rules provided by the IANA (Internet Assigned Numbers Authority).
This ensures accurate time synchronisation without the need for manual adjustments during seasonal changes.
If a light sensor has been added to a group, setting the time slot allows you to use the “Constant Light” function, which is based on a preset from the light sensor. This preset can be selected from the “Lux Set” drop-down menu in the time slot management screen.
If the sensor is a motion sensor, you can also adjust the timeout (minimum 1 minute), which determines the percentage of light dimming when no movement is detected.
Select one of the presets connected to the Dali2 brightness sensor
Percentage of group dimming in the absence of movement
Standby timeout of the last motion detection by the sensor
Secondary PIR Timeout (HOLD TIME)
With version 1.1.0 of the application, a secondary PIR timeout level has been introduced. This optional timeout activates after the first inactivity period detected by the motion sensor. When the PIR sensor no longer detects presence, at the end of the first timeout the system does not immediately switch off the lights. Instead, it applies a progressive dimming down to the configured value, maintaining reduced illumination for the duration defined in the secondary timeout. Only when this second timeout expires are the lights fully switched off. This feature can be configured individually for each time slot and allows for a more natural and comfortable management of environments, avoiding abrupt switch‑offs in cases of slow or infrequent movement.
Management of Devices with System‑Wide Override
Global Devices are devices that act on the entire system, overriding the programming configured for individual groups. Through this function, it is possible to manage simple buttons and DALI keypads with up to 4 channels, ensuring manual control of lighting independently from programmed scenarios.
How to Activate a Global Device
To display a device within the Global Devices menu, access the Devices menu, select the desired device, and assign it to the Global Group. Only after this operation will the device be visible and manageable from this section.
You can connect one or more DALI keypads to the system, with up to 4 independent channels. Each button on the keypad can be configured individually by choosing between two operating modes:
Features Introduced with the Application Update